Chemistry - Overall Migration - 1 simulant (A, B, C or D1) - multiple use

Reusable devices contacting various foods through repeated cycles require migration assessment across simulants demonstrating consistent safety regardless of food type variability over device lifetime. Multiple-use overall migration in liquid simulants demonstrates migration stability through repeated exposure cycles across different simulant types. This comprehensive testing reveals whether migration increases due to material degradation from repeated food contact, decreases as mobile substances deplete through cumulative extraction, or maintains stability indicating well-controlled material performance. Critical for reusable devices with repeated food contact requiring safety demonstration across device lifetime, validating that cleaning procedures between uses don't alter migration characteriztics through surface modification, and demonstrating that safety margins remain adequate throughout intended reuse cycles. For reusable medical nutrition equipment, testing across simulants validates performance with various enteral feed compositions from aqueous to fatty formulations, repeated exposure and cleaning cycles don't compromise migration control through material changes, and initial high migration stabilizes to lower levels through extractable depletion. The multi-simulant repeated testing approach reveals simulant-specific migration behavior identifying whether certain food types cause enhanced extraction, enables comparison across simulants determining worst-case conditions, and supports use recommendations specifying compatible food types when migration varies significantly. Manufacturing validation for reusable devices confirms formulations provide acceptable migration across all relevant simulants throughout design life, processing achieves migration levels maintaining compliance even after repeated extractions, and validation studies demonstrate safety under conditions representing actual clinical use patterns.

No.
1007022
Method
Multiple cycles per customer, gravimetry
Analyses category
Sample type
Finished device, Primary container, Secondary packaging, Bulk material
Sample requirement (type)
Sterile or non sterile
Sample quantities
2 product, 200 cm2, 20 gram
Lead Time Standard (Days)
unavailable
Lead Time Express (Days)
unavailable
Lead Time Super Express (Days)
unavailable
Test facility
In House
GLP
No
Add this test to cart to request an offer.

Do you need some help?

Other similar tests

EU 10/2011, EN 1186-1, EN 1186-13, SR 817.023.21
Chemistry - Overall Migration - 1 simulant (D2) - single use

Fatty food contact represents worst-case migration scenarios - lipophilic substances partition preferentially into oils making D2 simulant testing critical for comprehensive safety assessment of food contact materials. Single-use migration testing with D2 (oil) simulant represents fatty food contact often showing highest migration levels due to lipophilic substance extraction following EU regulations. This worst-case simulation ensures devices remain safe even with fatty food contact through aggressive extraction conditions, accommodates materials containing lipophilic additives that aqueous simulants miss, and provides conservative safety assessment protecting consumers from underestimated exposure. Critical for devices potentially contacting fatty foods including feeding tubes for high-fat nutritional formulations, pharmaceutical lipid preparations used in parenteral nutrition, or comprehensive migration assessment requiring oil simulant testing alongside aqueous evaluations. For medical devices with lipophilic extractables, D2 testing reveals maximum migration that other simulants underestimate, validates material selections considering worst-case fatty food scenarios, and supports risk assessment using highest exposure values for conservative safety evaluation. The oil simulant efficiently extracts plasticizers, stabilizers, and other lipophilic additives that remain largely immobile in aqueous simulants, providing realistic assessment of fatty food contact exposures. Manufacturing validation ensures materials achieve acceptable migration even under worst-case oil extraction, formulation modifications reducing lipophilic extractables demonstrate improved performance in D2 testing, and specifications account for elevated D2 migration setting appropriate limits.

EU 10/2011, EN 1186-1, EN 1186-13, SR 817.023.21
Chemistry - Overall Migration - 1 simulant (D2) - multiple use

Reusable devices experiencing repeated fatty food contact require demonstration that lipophilic substance migration remains controlled throughout device lifetime despite aggressive extraction conditions. Multiple-use migration testing with D2 simulant through repeated cycles demonstrates long-term safety with fatty food contact revealing whether oil exposure causes progressive material degradation or maintains stable migration levels. This extended testing reveals whether repeated oil extraction causes material swelling or degradation increasing migration, demonstrates eventual stabilization as extractable lipophilic substances deplete, or identifies concerning trends requiring use limitations or enhanced monitoring. Essential for reusable devices contacting fatty substances validating safety throughout intended use duration, equipment used with lipid-based nutritional formulations demonstrating maintained compliance, and regulatory submissions requiring proof that repeated oil exposure doesn't compromise migration safety. For reusable medical nutrition equipment processing high-fat enteral feeds, testing validates that repeated lipid contact doesn't progressively extract additives through swelling, cleaning between uses adequately removes absorbed oils preventing accumulation, and material integrity maintains acceptable migration despite potentially plasticizing oil exposure. The serial D2 extraction approach simulates extended device use under challenging conditions, reveals whether protective barriers resist oil penetration throughout lifetime, and demonstrates whether initial elevated migration stabilizes to lower levels through extractable depletion. Manufacturing validation confirms material selections withstand repeated oil exposure without excessive migration increases, processing produces materials with migration stability under aggressive conditions, and design life determination accounts for migration behavior under repeated fatty food contact scenarios.

ISO 10993-18, EU 10/2011
Chemistry - BDDE analysis

Epoxy resins and coatings contain BADGE (Bisphenol A diglycidyl ether) and derivatives that migrate into contacted substances creating endocrine disruption concerns requiring sensitive detection distinguishing BADGE from related compounds. BADGE (Bisphenol A diglycidyl ether) analysis by GC-MS targets epoxy components that migrate from coatings and adhesives with methodology preventing hydrolysis while ensuring complete detection. Careful handling prevents BADGE hydrolysis to hydroxylated derivatives during analysis, derivatization ensures complete detection of BADGE and transformation products, and chromatographic separation distinguishes BADGE from structurally similar compounds. Critical for devices with epoxy adhesives requiring validation that curing adequately reacts BADGE preventing migration, coated metal components where epoxy linings protect contents but potentially release BADGE, and demonstrating compliance with restrictions on bisphenol-related compounds increasingly targeted by regulations. For medical devices using epoxy coatings in fluid pathways, BADGE testing validates that coating formulation and cure conditions minimize residual monomers, migration under simulated use remains below regulatory limits, and aging doesn't increase BADGE release through coating degradation. The analysis accommodates various BADGE derivatives including hydrolyzed products formed during migration or storage, quantifies both BADGE monomers and higher molecular weight oligomers, and supports risk assessment calculating exposure from measured levels. Manufacturing validation confirms epoxy curing achieves adequate BADGE reaction, coating application processes don't introduce excess BADGE through incomplete mixing, and quality control detects batches with elevated BADGE requiring corrective action. The testing supports "BPA-free" claims by confirming epoxy alternatives don't introduce BADGE or similar bisphenol-derived epoxy compounds with comparable endocrine activity concerns.

ISO 10993-18, EU 10/2011
Chemistry - Bisphenol (without extraction)

Direct bisphenol analysis in liquid samples eliminates extraction complexity yet maintains sensitivity - testing extracts, process liquids, or formulations requires rapid methods avoiding elaborate sample preparation while achieving regulatory detection limits. Direct bisphenol analysis in liquid samples using GC-MS with BSTFA derivatization ensures complete detection of BPA and related compounds through chemical derivatization enhancing volatility and detectability. This rapid approach eliminates extraction steps reducing analysis time and cost while achieving sensitivity below regulatory thresholds protecting against endocrine disruption concerns. Critical for analyzing device extracts testing leachable bisphenol content from polycarbonate or epoxy materials, monitoring BPA in liquid products ensuring purity meeting regulatory requirements, and validating "BPA-free" claims for liquid-contact materials demonstrating absence below detection limits. The BSTFA derivatization converts bisphenols to trimethylsilyl derivatives improving GC separation and mass spectral detection, enabling sensitive quantification in complex matrices containing interfering substances. For medical devices contacting aqueous solutions, direct analysis of extracts reveals bisphenol leaching under simulated use conditions, supporting biocompatibility assessment and toxicological risk evaluation. Manufacturing applications include validation testing process liquids ensuring BPA-free status, quality control of incoming liquid components, and investigation of unexpected estrogenic activity potentially caused by bisphenol contamination. The method accommodates various bisphenol analogs beyond BPA including BPS and BPF enabling comprehensive screening as regulations expand beyond traditional BPA restrictions to encompass structurally related compounds with similar endocrine activity.

ISO 10993-18, EU 10/2011
Chemistry - Bisphenol (extraction included)

Solid materials containing bisphenols require extraction releasing these endocrine disruptors before analysis - polycarbonate plastics, epoxy coatings, and thermal paper all harbor bisphenols needing specialized extraction for quantification. Bisphenol analysis with extraction addresses solid materials and complex matrices using GC-MS with derivatization for comprehensive detection following sample extraction. The extraction approach ensures complete recovery of free and bound bisphenols from various materials including polycarbonate where BPA comprises the polymer backbone, epoxy resins where bisphenols serve as curing agents, and thermal papers using bisphenols as color developers. Essential for validating BPA-free claims in medical devices demonstrating polycarbonate alternatives or coatings don't contain bisphenols, investigating endocrine disruption concerns when biological testing reveals estrogenic activity, and demonstrating compliance with expanding bisphenol restrictions across global markets. The extraction methodology releases bisphenols from polymer matrices through solvent extraction or thermal desorption, quantifies both monomeric bisphenols and oligomers that migrate during use, and accommodates various sample forms from powders to fabricated devices. For medical device materials, bisphenol testing validates that BPA-free formulations genuinely lack these compounds rather than containing structural analogs with similar endocrine activity. Manufacturing validation confirms processing doesn't introduce bisphenol contamination from equipment or additives, alternative materials marketed as BPA-free don't contain related bisphenols like BPS or BPF, and sterilization doesn't cause polymer degradation releasing bisphenols. The testing supports regulatory submissions demonstrating compliance with bisphenol restrictions, responds to customer requirements increasingly specifying bisphenol-free materials, and addresses stakeholder concerns about endocrine disruption from medical device exposure.