Biocomp - in vivo acute systemic toxicity

Systemic toxicity from medical devices represents the ultimate safety concern - localized reactions prove manageable yet substances entering bloodstream and distributing systemically can cause organ damage, neurological effects, or death. Acute systemic toxicity testing per ISO 10993-11 evaluates potential adverse effects from systemic exposure to device extracts through intravenous and intraperitoneal injection in mouse models, providing fundamental safety data required for all medical devices by ISO 10993-1. The protocol involves injecting both polar and non-polar extracts prepared according to ISO 10993-12, with clinical observations over 72 hours detecting various toxic endpoints including mortality, morbidity, behavioral changes, and organ-specific effects. Regulatory requirements mandate systemic toxicity testing for all device categories beyond surface devices with intact skin contact - implants where chronic substance leaching creates systemic exposure, blood-contacting devices where extractables directly enter circulation, and externally communicating devices where substances might reach systemic circulation through breached barriers. The dual injection route approach ensures detection of toxicity regardless of absorption kinetics - intravenous administration providing immediate systemic exposure while intraperitoneal injection simulates slower absorption from tissue spaces. For devices with extended contact duration, systemic toxicity testing demonstrates that cumulative exposure throughout intended use remains safe, supporting risk assessment per ISO 10993-17. The 72-hour observation captures both acute effects occurring immediately and delayed toxicity manifesting hours after exposure, providing comprehensive safety assessment. Manufacturing validation confirms processing reduces extractable toxins, sterilization doesn't generate systemically toxic degradation products, and material changes don't introduce new safety concerns requiring retesting.

No.
1006214
Method
Mouse systemic injection, polar/non-polar extracts
Stage category
Analyses category
Sample type
Finished device, Bulk material
Sample requirement (type)
Sterile or non sterile
Sample quantities
120 cm2
Lead Time Standard (Days)
30
Lead Time Express (Days)
unavailable
Lead Time Super Express (Days)
15
Test facility
Partner Lab
GLP
Yes
Add this test to cart to request an offer.

Do you need some help?

Other similar tests

ISO 10993-1, ISO 10993-4
Biocomp - Hemocompatibility - Hemolysis (material induced)

Blood compatibility determines success for cardiovascular devices and extracorporeal circuits - hemolysis destroys red blood cells causing anemia, jaundice, and potential renal failure making this testing critical for blood-contacting applications. Hemolysis testing following ISO 10993-4 evaluates red blood cell damage potential using human erythrocytes, providing clinically relevant assessment of blood compatibility required for all blood-contacting devices. The protocol accommodates both direct contact methods placing devices in blood and extract testing evaluating leachable substances, with spectrophotometric measurement of released hemoglobin quantifying damage relative to controls. Essential device categories include all cardiovascular implants where chronic blood contact demands demonstrated hemocompatibility, extracorporeal circuits processing blood outside body, blood collection devices where hemolysis compromises diagnostic accuracy, and any intravascular device contacting flowing blood. The test detects both mechanical hemolysis from surface roughness causing physical damage and chemical hemolysis from leachables disrupting cell membranes, with regulatory submissions requiring hemolysis rates below 5% for most devices. For cardiovascular stents and heart valves, low hemolysis proves critical preventing anemia from chronic red cell destruction, while dialysis membranes require assessment ensuring blood processing doesn't cause unacceptable cell damage. The testing validates surface treatments reducing hemolytic potential, confirms material selections don't release hemolytic substances, and demonstrates that sterilization doesn't create surface characteriztics promoting hemolysis. Manufacturing quality control uses hemolysis testing detecting surface contamination or roughness increases that could elevate hemolysis rates, supporting process control maintaining blood compatibility throughout production.

ISO 10993-1, ISO 10993-23
Biocomp- Acute oral irritation

Dental materials, orthodontic devices, and oral drug delivery systems contact oral mucosa under unique conditions - saliva continuously bathes surfaces while mastication creates mechanical stress, demanding specialized irritation assessment beyond standard dermal testing. Oral irritation testing evaluates mucosal compatibility for dental and oral medical devices through specialized protocols using hamster cheek pouch or other validated models assessing tissue responses from repeated exposure. The test assesses local tissue responses following repeated exposure simulating clinical use patterns, capturing both immediate irritation and cumulative effects from chronic contact that single exposures miss. Critical applications encompass dental materials including composites and cements contacting gingival tissues, orthodontic devices worn continuously for months or years, oral prosthetics like dentures contacting mucosa during eating and speaking, and oral drug delivery systems releasing therapeutic agents requiring demonstrated mucosal compatibility. The hamster cheek pouch model offers advantages including easy visualization of tissue responses through transparent mucosa, established historical controls enabling comparative assessment across studies, and physiological relevance to human oral cavity. For materials causing borderline responses, the testing reveals whether intensity warrants usage restrictions, enhanced monitoring protocols, or material reformulation preventing clinical adverse events. The repeated exposure protocol simulates actual clinical use more accurately than single applications, revealing cumulative toxicity or sensitization that acute testing misses. Regulatory submissions for dental devices require mucosal compatibility data demonstrating low irritation supporting safe chronic use, with results influencing product labeling and patient instructions about potential sensitivity.

ISO 10993-1, ISO 10993-23
Biocomp - In Vitro Irritation Test (Medical device 10993-23)

Animal testing faces increasing ethical scrutiny and regulatory restrictions - validated alternative methods reducing animal use while maintaining predictive accuracy represent the future of safety assessment. In vitro skin irritation testing per ISO 10993-23 using MatTek EpiDermâ„¢ reconstructed human epidermis provides human-relevant safety assessment while eliminating animal use through validated tissue construct methodology. The validated protocol exposes tissue constructs to test materials with subsequent MTT viability assessment providing quantitative data that predicts human skin responses, correlating with in vivo Draize scores through established prediction models. The reconstructed human epidermis model incorporates normal human keratinocytes forming stratified epithelium with functional barrier properties including stratum corneum, providing physiologically relevant tissue responses. Regulatory acceptance continues expanding with EU authorities preferring in vitro methods when validated alternatives exist, while global harmonization efforts promote alternative method adoption reducing animal testing. For medical device manufacturers, in vitro irritation testing provides earlier safety assessment during development screening materials before expensive in vivo studies, enables efficient material comparison testing multiple candidates rapidly, and demonstrates corporate responsibility regarding animal welfare. The quantitative viability data enables dose-response assessment revealing concentration-dependent effects, supporting formulation optimization minimizing irritation while maintaining functionality. Manufacturing validation confirms processing doesn't increase skin irritation potential, sterilization doesn't generate irritating degradation products, and aging maintains acceptable irritation profiles throughout shelf life. The human-derived tissue provides more relevant prediction of human responses than animal models, potentially reducing clinical surprises from species differences in skin sensitivity or metabolism.