Chemistry - EG residues

Ethylene glycol contamination from unexpected sources creates toxicity risks - antifreeze exposure, polyester manufacturing residues, or sterilization system leaks introduce this nephrotoxic compound requiring sensitive detection and quantification. Ethylene glycol residue testing addresses contamination from antifreeze exposure during equipment maintenance, polyester manufacturing where glycol represents polymerization residue, or sterilization processes where system leaks introduce this toxic compound. GC-FID quantification following ISO 10993-7 and 10993-12 extraction provides reliable measurement of this toxic compound that causes renal failure through metabolic conversion to oxalic acid. Critical for PET-based devices where residual glycol indicates incomplete polymerization compromising material properties and introducing toxicity, hemodialysis components with direct blood contact where glycol exposure causes severe systemic toxicity, and validating cleaning after equipment maintenance with glycol-containing fluids preventing cross-contamination to products. For polyethylene terephthalate medical devices, ethylene glycol serves as the diol component in polymerization with residual monomer indicating inadequate reaction completion or material degradation. The testing becomes essential when investigating unexpected cytotoxicity potentially caused by glycol contamination, validating new material suppliers ensuring manufacturing processes achieve complete polymerization, or qualifying alternative sterilization methods where some techniques use glycol-based systems. Manufacturing validation confirms processing adequately removes or reacts residual glycol, storage doesn't cause material degradation releasing glycol from polymer chains, and cleaning procedures eliminate glycol from equipment before product processing.

No.
100704
Method
Ethylene glycol by GC-FID after extraction
Industry category
Analyses category
Sample type
Finished device, Bulk material, Liquid sample
Sample requirement (type)
Sterile or non sterile
Sample quantities
1 product, 5 ml
Lead Time Standard (Days)
10
Lead Time Express (Days)
5
Lead Time Super Express (Days)
3
Accredited
Yes
Test facility
In House
GLP
No
Add this test to cart to request an offer.

Do you need some help?

Other similar tests

ISO 10993-12, ISO 9377-2
Chemistry - Total Hydrocarbons (THC) - analysis

Petroleum-based contamination represents the silent killer of biocompatibility - invisible hydrocarbon residues from machining and assembly processes trigger cytotoxicity, inflammatory responses, and device failures that appear only after expensive biological testing reveals problems. Following ISO 10993-12 extraction requirements and ISO 9377-2 analytical methodology, Total Hydrocarbon analysis provides comprehensive assessment of oil and grease contamination that could compromise device biocompatibility or functionality. The 24-hour hexane extraction at controlled temperature ensures complete recovery of petroleum-based contaminants while the GC-MS analysis delivers both quantitative measurement and qualitative identification of specific hydrocarbon sources. Manufacturing validation particularly benefits from THC analysis when qualifying new machining centers where cutting fluid contamination must be controlled, validating parts washing systems to demonstrate residue removal effectiveness, or establishing cleanliness specifications for outsourced components preventing supplier contamination from reaching finished devices. The chromatographic fingerprint distinguishes between different contamination sources - mineral oils from machining operations, silicone lubricants from assembly processes, or polymer additives from injection molding - enabling targeted remediation strategies addressing specific contamination origins. For implantable devices undergoing biocompatibility testing per ISO 10993, hydrocarbon residues often explain unexpected cytotoxicity or inflammatory responses, as even trace petroleum contamination can trigger adverse biological reactions through direct cellular toxicity or immune system activation. Critical applications include orthopedic implants where hydrocarbon residues interfere with osseointegration by preventing protein adhesion, cardiovascular devices where oil contamination affects hemocompatibility and thrombogenicity, and drug-device combinations where hydrocarbons alter drug stability or release profiles through partitioning effects.

ISO 10993-7, ISO 10993-12
Chemistry - EtO/ECH residues

Ethylene oxide sterilization effectively kills microorganizms yet leaves invisible toxic residues that cause severe adverse events - hemolysis, neurotoxicity, and sensitization reactions make residual monitoring mandatory for patient safety. Ethylene oxide and ethylene chlorohydrin residual testing per ISO 10993-7 represents mandatory safety validation for all EtO-sterilized medical devices, with validated GC-FID headspace methodology achieving detection limits well below allowable limits established by ISO 10993-17. The validated methodology ensures accurate patient exposure assessment through simulated-use extraction protocols, with three sequential extractions generating dissipation curves modeling residue depletion during clinical use representing realistic patient exposure. Critical for validating aeration parameters ensuring adequate residue removal before product release, supporting batch release decisions demonstrating compliance with safety limits, and demonstrating regulatory compliance with exposure limits particularly stringent for pediatric and long-term implantable devices. The analysis enables optimization of sterilization cycles balancing microbial efficacy requiring adequate EtO exposure against minimized residue formation from reduced chemical contact and lower temperatures. For implantable devices particularly those contacting blood or neural tissue, EtO residues cause hemolysis and neurotoxicity at elevated levels, making rigorous testing essential for patient safety. The ethylene chlorohydrin measurement proves critical as this reaction product between EtO and chlorine forms during sterilization or aeration, exhibiting greater toxicity than EtO itself requiring separate quantification and limits. Manufacturing validation establishes aeration times achieving consistent residue reduction, while routine testing verifies process control maintaining residues within specifications across production lots and sterilization cycles.