Chemistry - ICP-MS screening (40 elements)

Metallic contamination from complex supply chains creates the terrifying unknown - trace elements from raw materials, manufacturing equipment, or environmental exposure accumulate undetected until biological testing reveals cytotoxicity or regulatory screening finds banned substances. Multi-element screening by ICP-MS following ISO 10993-12 extraction provides semi-quantitative analysis of 40 elements, enabling comprehensive assessment of metallic contamination and elemental composition that targeted analysis would miss. This broad screening approach identifies unexpected elemental contaminants from complex supply chains where multiple vendors contribute materials, novel materials with unknown elemental profiles, or manufacturing processes introducing trace metals through equipment wear or environmental exposure. The semi-quantitative data guides subsequent quantitative analysis by identifying elements of concern requiring definitive measurement, supporting efficient use of analytical resources while ensuring comprehensive safety evaluation captures all potential risks. Applications include initial material characterization during development identifying baseline elemental composition, investigation of unexpected biological responses potentially linked to metallic contamination triggering inflammatory reactions, and screening for restricted elements in global markets where regulations vary by region. For medical device manufacturers with international distribution, elemental screening ensures products don't contain banned substances like cadmium or hexavalent chromium that regulatory markets prohibit. The 40-element panel captures traditional toxic metals including lead, mercury, and arsenic alongside emerging concerns like cobalt and nickel causing sensitization, rare earth elements from manufacturing processes, and catalyst residues from polymer production. Extraction following ISO 10993-12 protocols at physiologically relevant conditions ensures clinical relevance, while ICP-MS sensitivity enables detection at toxicologically significant levels supporting risk assessment. The screening proves invaluable when validating new suppliers, investigating lot-to-lot variations suggesting elemental contamination changes, or qualifying manufacturing process modifications that might introduce metallic contamination.

No.
1006071
Method
Water extraction, semi-quantitative scan for 40 elements
Stage category
Analyses category
Sample type
Finished device, Bulk material
Sample requirement (type)
Sterile or non sterile
Sample quantities
15 cm2, 0,5 gram
Lead Time Standard (Days)
15
Lead Time Express (Days)
10
Lead Time Super Express (Days)
5
Test facility
Partner Lab
GLP
No
Add this test to cart to request an offer.

Do you need some help?

Other similar tests

Ph.Eur. 2.2.44, Ph.Eur. Mono. 0008, Ph.Eur. Mono. 0169, USP 643, EN 1484, ASTM G136-03
Chemistry - TOC - water analysis

Water touches every aspect of pharmaceutical and medical device manufacturing, yet organic contamination invisible to standard testing can compromise products, harbor dangerous biofilms, and signal system failures before they become catastrophic. Total Organic Carbon analysis serves as the cornerstone of water quality assessment in pharmaceutical, medical device, and industrial applications, quantifying organic contamination in water systems critical for manufacturing, production, and environmental monitoring following EN 1484 and ASTM G136-03 standards. The combustion-oxidation method delivers precise measurements with detection limits suitable for ultrapure water validation through process water characterization, enabling comprehensive contamination assessment from pharmaceutical water systems to industrial process monitoring. Critical applications include validation of water treatment systems where TOC trending reveals membrane fouling or resin exhaustion, verification of cleaning processes where organic levels indicate sanitization effectiveness, and environmental compliance monitoring where discharge limits require documented organic content. The analysis supports quality control programs by establishing baseline values that enable detection of system breaches, trending water quality over time to identify gradual degradation suggesting maintenance needs, and correlating organic levels with microbial growth patterns. Particularly valuable for pharmaceutical water systems where organic contamination indicates microbial growth potential, biofilm formation creating endotoxin sources, or system degradation requiring intervention before contamination compromises products. For medical device manufacturers, TOC monitoring validates that rinse water quality supports cleaning validation claims and prevents organic transfer to devices during final processing. Results enable informed decisions about system maintenance timing, process improvements targeting contamination sources, and regulatory compliance strategies supporting USP and Ph. Eur. water specifications that increasingly emphasize organic contamination control.

ISO 10993-12, Ph.Eur. 2.2.44, USP 643, EN 1484
Chemistry - TOC (medical device) - analysis

Manufacturing residues invisible to visual inspection accumulate on medical device surfaces - machining coolants, mold releases, assembly lubricants - creating biocompatibility failures, cytotoxicity surprises, and regulatory obstacles that derail product launches after substantial development investment. Total Organic Carbon analysis for medical devices following the rigorous extraction protocols of ISO 10993-12 ensures that test conditions accurately simulate clinical use while meeting the analytical requirements of EN 1484, Ph. Eur. 2.2.44, and USP <643>. This comprehensive approach has become indispensable for three critical validation scenarios: cleaning validation during manufacturing line qualification where TOC verifies residue removal to safe levels, biocompatibility testing per ISO 10993-1 providing foundational chemical characterization before biological evaluation, and validation of cleaning processes for reusable medical devices according to AAMI ST98 demonstrating consistent organic residue removal. During manufacturing validation, TOC analysis verifies that cleaning processes consistently remove production residues - machining coolants, mold releases, adhesives, and assembly lubricants - to levels that won't compromise biocompatibility or device functionality. The extraction at physiologically relevant temperatures ensures complete recovery of both loosely bound surface contaminants and absorbed organic materials that could leach during clinical use, providing worst-case assessment. For biocompatibility assessment, TOC data provides the foundational chemical characterization required before biological testing, helping predict and interpret cytotoxicity results while supporting toxicological risk assessments per ISO 10993-17. When validating reprocessing procedures for reusable devices, TOC analysis proves that cleaning protocols achieve consistent organic residue removal across different soil challenges and device designs. The quantitative nature enables statistical process validation, demonstrating six-sigma cleaning effectiveness that visual inspection alone cannot provide.

ISO 10993-12, Ph.Eur. 2.2.44, USP 643, EN 1484
Chemistry - TOC (medical device) - method validation

Testing methods that fail to account for device-specific interference generate unreliable data that undermines cleaning validation, biocompatibility assessment, and regulatory submissions built on flawed measurements. Method validation for Total Organic Carbon analysis establishes that specific device materials won't interfere with accurate contamination measurement, a critical requirement before relying on TOC data for product release or cleaning validation decisions. Following ISO 10993-12 extraction protocols tailored to device clinical use and EN 1484 analytical requirements, this validation demonstrates recovery of organic contamination from unique material matrices through spiking studies with sucrose at multiple concentration levels. The validation process reveals whether device materials absorb organic compounds creating artificially low recovery, release interfering substances that elevate baseline readings, or require modified extraction conditions to achieve accurate results reflecting true contamination levels. For complex multi-material devices, validation ensures that extraction parameters - whether aggressive conditions for implantables or mild conditions for surface-contacting devices - effectively remove contaminants from all components without causing material degradation that artificially elevates TOC levels through polymer breakdown. Recovery studies typically target 70-130% spike recovery across three concentration levels spanning expected contamination range, establishing method linearity and detection limits specific to device materials and manufacturing processes. The validation data supports regulatory submissions by demonstrating that TOC testing produces reliable, reproducible results regardless of batch-to-batch material variations, supplier changes, or manufacturing process modifications. Failed validation reveals methodology limitations requiring optimization before expensive product testing, preventing wasted resources on unreliable data.

ISO 10993-12, ISO 9377-2
Chemistry - Total Hydrocarbon (THC) - method validation

Validation failures discovered after expensive testing waste resources and delay projects, making upfront method validation essential for avoiding costly surprises during product development. Method validation for hydrocarbon analysis ensures accurate quantification despite potential interference from polymer additives, plasticizers, or other extractables that could mask or mimic petroleum contamination. Following ISO 10993-12 and ISO 9377-2 requirements, validation uses hydrocarbon reference standards to demonstrate recovery from specific materials while confirming that hexane extraction doesn't dissolve device components creating false-positive results. The validation process optimizes extraction parameters for device materials - duration, temperature, and solvent volume - balancing complete hydrocarbon recovery against material compatibility that prevents polymer dissolution artificially elevating results. For multi-component devices, validation confirms that all materials tolerate hexane exposure without degradation while still releasing trapped hydrocarbons from manufacturing processes. The GC-MS method validation establishes chromatographic conditions that separate hydrocarbon peaks from interfering substances, enabling accurate quantification even in complex matrices containing multiple organic species. Recovery studies across expected contamination range demonstrate method linearity and establish detection limits appropriate for cleanliness specifications, ensuring sensitivity adequate for biocompatibility risk assessment. The validation prevents false conclusions about contamination levels that could lead to either unnecessary process changes based on method artifacts or dangerous underestimation of actual hydrocarbon contamination threatening biocompatibility.

Ph.Eur. 2.9.19, Ph.Eur. Mono. 0008, Ph.Eur. Mono. 0169, USP 788, ISO 21501-3, AAMI TIR42
Cleaning - Sub-visible particles - USP 788, EP 2.9.19 - analysis

Microscopic particles invisible during visual inspection accumulate in injectable products and medical devices, creating thrombosis risks, inflammatory responses, and device malfunctions that threaten patient safety with every administration or implantation. Sub-visible particle analysis by light obscuration following Ph. Eur. 2.9.19, USP 788, ISO 21501-3, and AAMI TIR42 provides critical quality assessment for parenteral devices, ophthalmic products, and injectables where particulate contamination creates thrombosis risks, inflammatory responses, and product quality failures threatening patient safety. This high-sensitivity optical technique quantifies particles from 1 to 100 microns extracted from products into particle-free water or isopropanol, detecting contamination invisible to visual inspection but clinically significant at concentrations triggering regulatory limits. Injectable medical devices including prefilled syringes, administration sets, and implantable drug delivery systems require particulate testing demonstrating compliance with pharmacopeial limits protecting patients from particulate embolism, granuloma formation, and device malfunction caused by particle accumulation at critical surfaces. Ophthalmic devices and contact lens products demand extremely low particle limits given eye sensitivity to foreign material, with testing supporting claims of particle-free manufacturing and validating cleaning processes removing manufacturing residues. The methodology's 1 micron resolution detects particles well below visible thresholds, providing sensitive contamination monitoring that identifies process problems - inadequate cleaning, component degradation, packaging failures - before visible particles develop requiring costly investigations and potential recalls. Manufacturers establishing particle specifications for new products use light obscuration data to set realistic limits balancing patient safety against manufacturing capability.

ISO 10993-12, ISO 10993-18, USP 1663, USP 1664, EPA 8260
Chemistry - GC screening - VOC

Unexpected cytotoxicity discovered during biocompatibility testing after years of development represents every device manufacturer's nightmare - invisible volatile compounds leaching from materials trigger cell death, derail regulatory submissions, and force expensive redesigns. Comprehensive volatile organic compound characterization following ISO 10993-18 and ISO 10993-12 provides essential chemical safety data through headspace GC-MS analysis of water extracts capturing compounds most likely to cause biological responses. This polar extraction approach captures water-soluble volatiles including residual solvents from manufacturing, unreacted monomers from polymerization, polymer additives that migrate during processing, and degradation products formed during sterilization or aging - representing primary exposure risks for blood-contacting and implantable devices. The screening methodology identifies unexpected contamination that targeted methods would miss - crucial when suppliers change formulations without notification, sterilization produces reaction products between materials and sterilant, or aging generates degradation compounds not present in fresh materials. Each detected peak undergoes library matching and expert interpretation to identify chemical structures, enabling toxicological risk assessment per ISO 10993-17 that determines whether identified compounds pose safety concerns. For respiratory devices, anesthesia equipment, and neonatal products where patients inhale volatiles directly, this analysis provides critical safety data supporting biological evaluation plans and regulatory submissions. Blood-contacting devices require VOC screening because volatile compounds rapidly partition into blood causing systemic exposure, while implantable devices need characterization ensuring long-term leaching won't cause chronic toxicity. The water extraction simulates physiological conditions where aqueous body fluids contact devices, providing clinically relevant data about actual patient exposure rather than worst-case aggressive extractions that overestimate risk.

ISO 10993-12, ISO 10993-18, USP 1663, USP 1664, EPA 8270, EPA 525
Chemistry - GC screening - semi-polar SVOC

Device materials contain hundreds of chemical additives - plasticizers providing flexibility, stabilizers preventing degradation, processing aids enabling manufacturing - yet many migrate under clinical conditions causing toxicity that only comprehensive screening reveals. Semi-polar volatile and semi-volatile compound screening using isopropanol extraction followed by GC-MS analysis bridges the gap between water-soluble and non-polar contaminants, capturing moderately polar substances that represent significant exposure risks through intermediate polarity. Following ISO 10993-12 and 10993-18 protocols, this extraction approach at physiologically relevant temperatures ensures detection of plasticizers, antioxidants, UV stabilizers, and processing aids that migrate under clinical conditions but water extraction misses. The isopropanol extraction proves particularly effective for devices containing PVC where phthalate plasticizers provide flexibility but pose toxicological concerns, polyurethane where polar additives enable processing but can leach causing cellular toxicity, and silicone where semi-polar components provide material properties but migrate over time. Manufacturing validation uses this screening to verify removal of processing solvents that could remain absorbed in materials, confirm additive levels remain within specifications preventing excessive migration, and detect degradation products forming during sterilization through chemical reactions or thermal stress. The GC-MS methodology provides both identification through mass spectral library matching and semi-quantitative data estimating exposure levels for toxicological evaluation. Critical for drug-device combinations where semi-polar extractables affect drug stability through chemical interactions, contact lenses where migrating additives cause eye irritation, and long-term implants where chronic exposure to semi-polar compounds requires comprehensive safety assessment. The extraction temperature selection balances aggressive conditions ensuring detection against clinical relevance, typically using body temperature or slightly elevated conditions representing physiologically relevant worst-case scenarios.

ISO 10993-12, ISO 10993-18, USP 1663, USP 1664, EPA 8270, EPA 525
Chemistry- GC screening - non-polar SVOC

Lipophilic contamination from manufacturing persists invisible to water-based testing yet accumulates in fatty tissues causing systemic toxicity or interferes with cellular membranes triggering unexpected biological responses discovered only after expensive biological testing. Non-polar extraction using hexane followed by GC-MS analysis targets lipophilic contaminants including hydrocarbon residues from machining, non-polar plasticizers providing material flexibility, and hydrophobic additives preventing material degradation that water and isopropanol extractions miss entirely. Following ISO 10993-12 and 10993-18 requirements, this aggressive extraction ensures detection of substances that could accumulate in fatty tissues through lipid partitioning or interfere with lipid membranes causing cellular dysfunction. Critical for devices containing rubber components where non-polar additives including sulfur accelerators and antioxidants prevent degradation but migrate causing sensitization, metal devices with hydrocarbon lubricants from manufacturing requiring removal before sterilization, and any device where lipophilic contamination affects biocompatibility through membrane interactions or tissue accumulation. The comprehensive screening identifies unexpected non-polar contaminants from supplier changes introducing new additive packages, manufacturing variations where process modifications leave different residue patterns, or material interactions where components exchange additives during storage creating contamination absent from individual materials. The hexane extraction aggressively solubilizes hydrophobic substances providing worst-case assessment of potential exposure, supporting toxicological risk assessment calculating safety margins based on maximum possible leaching. For implantable devices, non-polar extractables assessment becomes critical because lipophilic compounds accumulate in adipose tissue surrounding implants, creating chronic exposure scenarios requiring comprehensive characterization and risk evaluation demonstrating patient safety.