Chemistry - ICP-MS screening (40 elements)

Metallic contamination from complex supply chains creates the terrifying unknown - trace elements from raw materials, manufacturing equipment, or environmental exposure accumulate undetected until biological testing reveals cytotoxicity or regulatory screening finds banned substances. Multi-element screening by ICP-MS following ISO 10993-12 extraction provides semi-quantitative analysis of 40 elements, enabling comprehensive assessment of metallic contamination and elemental composition that targeted analysis would miss. This broad screening approach identifies unexpected elemental contaminants from complex supply chains where multiple vendors contribute materials, novel materials with unknown elemental profiles, or manufacturing processes introducing trace metals through equipment wear or environmental exposure. The semi-quantitative data guides subsequent quantitative analysis by identifying elements of concern requiring definitive measurement, supporting efficient use of analytical resources while ensuring comprehensive safety evaluation captures all potential risks. Applications include initial material characterization during development identifying baseline elemental composition, investigation of unexpected biological responses potentially linked to metallic contamination triggering inflammatory reactions, and screening for restricted elements in global markets where regulations vary by region. For medical device manufacturers with international distribution, elemental screening ensures products don't contain banned substances like cadmium or hexavalent chromium that regulatory markets prohibit. The 40-element panel captures traditional toxic metals including lead, mercury, and arsenic alongside emerging concerns like cobalt and nickel causing sensitization, rare earth elements from manufacturing processes, and catalyst residues from polymer production. Extraction following ISO 10993-12 protocols at physiologically relevant conditions ensures clinical relevance, while ICP-MS sensitivity enables detection at toxicologically significant levels supporting risk assessment. The screening proves invaluable when validating new suppliers, investigating lot-to-lot variations suggesting elemental contamination changes, or qualifying manufacturing process modifications that might introduce metallic contamination.

No.
1006071
Method
Water extraction, semi-quantitative scan for 40 elements
Stage category
Analyses category
Sample type
Finished device, Bulk material
Sample requirement (type)
Sterile or non sterile
Sample quantities
15 cm2, 0,5 gram
Lead Time Standard (Days)
15
Lead Time Express (Days)
10
Lead Time Super Express (Days)
5
Test facility
Partner Lab
GLP
No
Add this test to cart to request an offer.

Do you need some help?

Other similar tests

ISO 10993-12, Ph.Eur. Mono. 0008, Ph.Eur. Mono. 0169
Chemistry - ICP-MS analysis (1st element) - Base

Semi-quantitative screening identifies potential problems but regulatory submissions and risk assessment demand definitive quantification - estimating contamination levels proves insufficient when patient safety decisions require precise measurements. Quantitative ICP-MS analysis for specific elements provides definitive measurement of metallic contamination following ISO 10993-12 extraction and EPA 200.8 methodology, delivering regulatory-grade data for elements of toxicological concern. This targeted approach delivers precise quantification supporting risk assessment per ISO 10993-17 that calculates safety margins comparing measured levels against allowable limits derived from toxicological data. The water extraction at physiologically relevant conditions ensures clinical relevance simulating actual patient exposure, while ICP-MS sensitivity enables detection at toxicologically significant levels often below one microgram per device. Critical for validating that implantable devices meet limits for carcinogenic metals like nickel and chromium where chronic exposure poses cancer risks, confirming blood-contacting devices won't release hemolytic elements like copper or zinc at levels causing red blood cell damage, and demonstrating that manufacturing processes adequately remove metallic contamination from machining, welding, or surface treatments. For permanent implants, quantitative elemental analysis supports lifetime exposure calculations required by ISO 10993-17, multiplying daily leaching rates by implant duration to calculate total patient exposure for comparison against toxicological thresholds. Cardiovascular devices require stringent limits because metallic ions directly enter bloodstream, while orthopedic implants need quantification ensuring wear debris and corrosion products don't exceed safe levels. The quantitative data enables statistical process control tracking elemental levels across manufacturing lots, detecting trends suggesting equipment degradation or raw material quality changes before contamination reaches action limits. Regulatory submissions require element-specific quantification with documented detection limits, calibration linearity, and measurement uncertainty supporting safety conclusions.

ISO 10993-12, Ph.Eur. Mono. 0008, Ph.Eur. Mono. 0169
Chemistry - ICP-MS analysis (1 element) - Each additional element

Comprehensive elemental characterization requires measuring multiple elements from precious analytical samples - repeating sample preparation and extraction for each element wastes material and time while introducing variability between measurements. Additional element quantification extends ICP-MS analysis to comprehensively characterize multi-element contamination profiles efficiently by analyzing the same extracted sample. Each additional element uses the same prepared extract and analytical run, maximizing data acquisition while minimizing sample consumption and analytical time through efficient use of instrumental capacity. This modular approach enables customized analysis targeting specific toxicological concerns where certain elements require quantification, regulatory requirements where markets demand specific element data, or manufacturing process validation needs assessing contamination from particular sources. Particularly valuable when initial screening reveals unexpected elements requiring quantification for risk assessment, investigating complex contamination patterns suggesting multiple sources requiring comprehensive profiling, or establishing elemental fingerprints for quality control tracking material consistency. For devices with multiple material components, comprehensive elemental analysis characterizes each material's contribution to total exposure, enabling targeted contamination control addressing specific sources. The approach proves cost-effective compared to individual element analysis because instrument setup, calibration, and quality control apply to all elements measured simultaneously, while sample preparation occurs once regardless of element count. Manufacturing investigations benefit from complete elemental profiles distinguishing between equipment wear introducing chromium and iron, environmental contamination contributing zinc and copper, or raw material impurities containing catalyst residues. The data supports root cause analysis by revealing contamination patterns - correlated elements suggesting common sources versus independent variation indicating multiple contamination routes requiring distinct corrective actions.

ISO 10993-12, ISO 10993-18, USP 1663, USP 1664
Chemistry - LC screening - semi-polar NVOC

Material polarity determines compound migration patterns - semi-polar substances represent the middle ground between water-soluble and lipophilic extractables, requiring intermediate polarity solvents for comprehensive detection. Semi-polar non-volatile compound screening using isopropanol extraction followed by LC-MS provides comprehensive characterization of moderately polar, non-volatile substances occupying the intermediate polarity range between water-soluble and lipophilic extractables. This ISO 10993-12 and 10993-18 compliant analysis captures additives with intermediate polarity including plasticizers and stabilizers, oligomers from polymer processing, and degradation products formed through oxidation or hydrolysis reactions. The isopropanol extraction effectively solubilizes semi-polar compounds while maintaining compatibility with LC-MS analysis through appropriate dilution or solvent exchange, enabling direct injection without extensive sample preparation. Critical for devices containing polyurethanes where semi-polar additives enable processing and provide material properties, modified polymers with grafted functional groups creating intermediate polarity, and materials with complex additive packages requiring comprehensive characterization across polarity ranges. The LC-MS methodology accommodates compounds too polar for GC analysis yet not sufficiently ionic for standard reverse-phase LC, using gradient elution separating compounds across wide polarity range. Manufacturing validation confirms that processing removes semi-polar solvents used in fabrication, sterilization doesn't generate semi-polar degradation products, and aging doesn't produce oxidation products requiring safety assessment. For implantable devices, semi-polar extractables assessment characterizes chronic exposure to moderately polar compounds that accumulate at implant-tissue interfaces, while cardiovascular devices need screening ensuring blood contact doesn't extract harmful semi-polar additives.