Use the filters to find the tests that you need or search by name.
Extraction then GC-MS with derivatization
Solvent extraction, GC-MS for 13 phthalate esters
Water extraction 72h at 37°C, HS-GC-MS analysis
IPA extraction 72h at 37°C, GC-MS screening
Hexane extraction 72h at 37°C, GC-MS analysis
Water extraction 72h at 50°C, GC-MS screening
Extraction in DMF, GC-FID quantification
Titration of aqueous extract
GC-MS analysis for butanediol diglycidyl ether
Direct GC-MS with BSTFA derivatization
Direct measurement at 25°C with conductivity cell
Ethylene glycol by GC-FID after extraction
Simulated use extraction, GC-FID headspace analysis
Additional extraction cycle for EO/ECH
Conditions per customer, Tenax extraction, GC/LC-MS
Volatile siloxane migration test on Tenax
Multiple cycles per customer, Tenax, GC/LC-MS
GC-MS quantification in CBD products
Multiple cycles per customer, gravimetry
Multiple cycles per customer in oil, gravimetric analysis
Conditions per customer in oil simulant, gravimetry
Conditions per customer in simulant, gravimetric analysis
Multiple cycles per customer, gravimetric measurement
Conditions per customer, gravimetric determination
Direct pH measurement at 25°C with calibrated electrode
Direct GC-MS analysis for 13 phthalates
DCM extraction, FTIR quantification at 1260 cm-1
Method validation with count standards at 10µm and 25µm
Direct water analysis by combustion/oxidation method
Recovery validation with hydrocarbon standard, GC-MS method
Hexane extraction 24h, GC-MS quantification
Extraction in particle-free water, light obscuration counting
Gravimetric analysis of residual water on devices
GC-MS for cannabinoid profile
ATR-FTIR spectrum comparison with reference
Complexometric titration or colorimetric test
ICP-MS analysis for heavy metals suite
Additional element quantification by ICP-MS
Quantitative analysis for single element after extraction
Water extraction, semi-quantitative scan for 40 elements
Hexane extraction, LC-MS analysis
Water extraction, LC-MS screening for non-volatiles
IPA extraction, LC-MS non-volatile screening
Particle extraction, SEM imaging + EDX elemental mapping
Additional SEM-EDX analysis on subsequent samples
UV spectrophotometry or ion chromatography
Evaporation of extract, gravimetric determination
LC-MS/MS for PFAS compounds (EU list)
Acid digestion, ICP-MS for heavy metals
Surface elemental analysis at 3 locations, depth <10nm
XRF analysis for Pb, Cd, As in food contact materials
XRF elemental screening for RoHS compliance